Fluorescence Microscope Filters are manufactured using advanced thin-film coating processes to meet the stringent requirements of fluorescence microscopy. These filters are optimized to deliver high sensitivity, steep spectral transitions, and minimal spectral overlap between excitation and emission bands—critical for producing clear, high-contrast fluorescence images.
Covering the emission spectra of a wide range of fluorophores, SOT’s filters support both standard and advanced microscopy techniques. Robust construction and environmentally qualified coatings ensure long-term stability and consistent optical performance, even in demanding laboratory environments. Custom solutions are available to match specific microscope platforms, detectors, and research needs.
Key Features
High Transmittance & Steep Cut-off: Optimized spectral edges reduce crosstalk and improve contrast for accurate fluorescence imaging.
Fluorophore-Optimized Designs: Engineered for common fluorophores (DAPI, FITC/EGFP, TRITC/PE, Cy5, etc.) to maximize sensitivity and resolution.
Advanced Coating Technology: Multilayer dielectric coatings deliver excellent durability, stability, and long service life.
Wide Standard Selection & Customization: Broad range of standard bandpass options with tailored CWL, FWHM, OD, and sizes available.
Microscopy-Ready Performance: Designed for demanding fluorescence microscopy workflows, from routine imaging to advanced research.
Coating Parameters
Parameter
Value
Transmittance
T ≥ 90%, T ≥ 95% (Customized)
Wavelength (CWL)
350-850 nm (Customization based on the customer’s requirements)
Bandwidth (FWHM)
20–80 nm (Customization based on the customer’s requirements)
Optical Density (OD)
ODavg ≥ 6, ODabs ≥ 5
Dimension
Conventional Dia 25 × 3.5 mm, Dia 25 × 5.0 mm (mounted)
Thickness
1.0 mm, 1.1 mm
Note
Product dimensions and other optical parameters can be customized.
Typical Fluorescence Microscope Filter Set
Fluorescent Group
Excitation Filter (nm)
Emission Filter (nm)
Dichroic Mirror (nm)
DAPI/Alexa Fluor 350™
BP375/28
BP460/55
DM415
Atto 425/ECFP/Amycan
BP430/24
BP480/30
DM450
FITC/EGFP/Alexa Fluor 488™
BP470/40
BP535/40
DM505
CY3™/TRITC/TAMRA
BP480/30
BP535/40
DM505
ROX/mCherry/Alexa Fluor 594™
BP530/40
BP605/55
DM565
CY5™/Alexa Fluor 647™
BP624/40
BP694/40
DM660
Common Fluorescence Microscope Filters
Model
Wavelength (CWL, nm)
Bandwidth (FWHM, nm)
Model
Wavelength (CWL, nm)
Bandwidth (FWHM, nm)
BP375/28
375 ±2
28 ±2
BP535/40
535 ±2
40 ±2
BP430/24
430 ±2
24 ±2
BP560/40
560 ±2
40 ±2
BP460/55
460 ±2
55 ±2
BP605/55
605 ±2
55 ±2
BP470/40
470 ±2
40 ±2
BP635/60
635 ±2
60 ±2
BP480/30
480 ±2
30 ±2
BP624/40
624 ±2
40 ±2
BP530/40
530 ±2
40 ±2
BP694/40
694 ±2
40 ±2
Common Fluorescence Microscope Dichroic Mirrors
Model
Transmission Range (nm)
Reflection Range (nm)
Model
Transmission Range (nm)
Reflection Range (nm)
DM415
435–700
340–400
DM600
615–700
450–590
DM450
465–680
380–445
DM605
620–750
450–595
DM505
515–700
450–490
DM655
670–750
450–645
DM565
575–700
450–555
DM660
675–750
450–600
Applications
Fluorescence Microscopy – High-contrast imaging for biological samples
Cell Biology & Histology – Detailed visualization of cellular structures
Immunofluorescence – Accurate detection of labeled proteins and antigens
Live-Cell Imaging – Real-time observation with minimal spectral interference
Molecular Biology – DNA, RNA, and protein expression studies
Need a custom fluorescence filter set? Share your fluorophore, excitation source, detector, and microscope platform—our engineers will optimize the spectral design for your application.